LC1D32F7 Schneider Contc Electric
- Control circuit voltage: 110V AC 50/60Hz
- Rated breaking capacity: 250A at 440V for power circuit conforming to IEC 60947
- Product certifications: BV, CCC, CSA, DNV, GL, GOST, RINA, UL
Product Description
From the TeSys LC1D series, a 3-pole (3 NO) category AC-1 / AC-3 contactor rated at 32A (AC-3) / 50A (AC-1) with a 110V AC coil.
Technical Specification
- Range: TeSys
- Product Name: TeSys D
- Product Or Component Type: Contactor
- Device Short Name: LC1D
- Contactor Application
- Motor control
- Resistive load
- Utilisation Category
- AC-4
- AC-1
- AC-3
- Poles Description: 3P
- Power Pole Contact Composition: 3 NO
- [Ue] Rated Operational Voltage
- <= 300 V DC for power circuit
- <= 690 V AC 25...400 Hz for power circuit
- [Ie] Rated Operational Current
- 32 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
- 50 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
- Motor Power Kw
- 15 kW at 380...400 V AC 50/60 Hz AC-3
- 7.5 kW at 220...230 V AC 50/60 Hz AC-3
- 18.5 kW at 500 V AC 50/60 Hz AC-3
- 18.5 kW at 660...690 V AC 50/60 Hz AC-3
- 15 kW at 415...440 V AC 50/60 Hz AC-3
- 7.5 kW at 400 V AC 50/60 Hz AC-4
- Motor Power Hp (Ul / Csa)
- 2 hp at 115 V AC 50/60 Hz for 1 phase motors
- 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
- 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors
- 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
- 20 hp at 460/480 V AC 50/60 Hz for 3 phases motors
- 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors
- Control Circuit Type: AC 50/60 Hz
- [Uc] Control Circuit Voltage: 110 V AC 50/60 Hz
- Auxiliary Contact Composition: 1 NO + 1 NC
- [Uimp] Rated Impulse Withstand Voltage: 6 kV conforming to IEC 60947
- Overvoltage Category: III
- [Ith] Conventional Free Air Thermal Current
- 50 A at <= 60 °C for power circuit
- 10 A at <= 60 °C for signalling circuit
- Irms Rated Making Capacity
- 550 A at 440 V for power circuit conforming to IEC 60947
- 140 A AC for signalling circuit conforming to IEC 60947-5-1
- 250 A DC for signalling circuit conforming to IEC 60947-5-1
- Rated Breaking Capacity: 550 A at 440 V for power circuit conforming to IEC 60947
- [Icw] Rated Short-Time Withstand Current
- 138 A <= 40 °C 1 min power circuit
- 260 A <= 40 °C 10 s power circuit
- 430 A <= 40 °C 1 s power circuit
- 60 A <= 40 °C 10 min power circuit
- 100 A 1 s signalling circuit
- 120 A 500 ms signalling circuit
- 140 A 100 ms signalling circuit
- Associated Fuse Rating
- 63 A gG at <= 690 V coordination type 1 for power circuit
- 63 A gG at <= 690 V coordination type 2 for power circuit
- 10 A gG for signalling circuit conforming to IEC 60947-5-1
- Average Impedance: 2 mOhm at 50 Hz - Ith 50 A for power circuit
- [Ui] Rated Insulation Voltage
- 600 V for power circuit certifications CSA
- 600 V for power circuit certifications UL
- 690 V for power circuit conforming to IEC 60947-4-1
- 690 V for signalling circuit conforming to IEC 60947-1
- 600 V for signalling circuit certifications CSA
- 600 V for signalling circuit certifications UL
- Electrical Durability
- 1.65 Mcycles 32 A AC-3 at Ue <= 440 V
- 1.4 Mcycles 50 A AC-1 at Ue <= 440 V
- Power Dissipation Per Pole
- 2 W AC-3
- 5 W AC-1
- Safety Cover: With
- Mounting Support
- Rail
- Plate