LC1D32P7 Schneider Contc Electric
- Control circuit voltage: 230V AC 50/60HZ
- Rated breaking capacity: 250A at 440V for power circuit conforming to IEC 60947
- Product certifications: BV, CCC, CSA, DNV, GL, GOST, RINA, UL
Product Description
From the TeSys LC1D series, a 3-pole (3 NO) category AC-1 / AC-3 contactor rated at 32A (AC-3) / 50A (AC-1) with a 230V AC coil.
Technical Specification
- Range: TeSys
- Product Name: TeSys D
- Product or Component type: Contactor
- Device short name: LC1D
- Contactor application:
- Motor control
- Resistive: load
- Utilisation Category:
- AC-1
- AC-3
- AC-4
- Poles Description: 3P
- Power pole contact composition: 3 NO
- [Ue] rated operational voltage:
- <= 300 V DC for power circuit
- <= 690 V AC 25...400 Hz for power circuit
- [Ie] rated operational current:
- 32 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
- 50 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
- Motor power KW:
- 15 kW at 380...400 V AC 50/60 Hz AC-3
- 7.5 kW at 220...230 V AC 50/60 Hz AC-3
- 18.5 kW at 500 V AC 50/60 Hz AC-3
- 18.5 kW at 660...690 V AC 50/60 Hz AC-3
- 15 kW at 415...440 V AC 50/60 Hz AC-3
- 7.5 kW at 400 V AC 50/60 Hz AC-4
- Motor power HP (UL / CSA)
- 2 hp at 115 V AC 50/60 Hz for 1 phase motors
- 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
- 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors
- 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
- 20 hp at 460/480 V AC 50/60 Hz for 3 phases motors
- 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors
- Control circuit type: AC 50/60 Hz
- [Uc] control circuit voltage: 230 V AC 50/60 Hz
- Auxiliary contact composition: 1 NO + 1 NC
- [Uimp] rated impulse withstand voltage: Conforming to IEC 60947
- [Ith] conventional free air thermal current:
- 50 A at <= 60 °C for power circuit
- 10 A at <= 60 °C for signalling circuit
- Standards:
- CSA C22.2 No 14
- EN 60947-4-1
- EN 60947-5-1
- IEC 60947-4-1
- IEC 60947-5-1
- UL 508
Complementary
- Coil technology: Without built-in suppressor module
- Minimum switching current: 5 mA for signalling circuit
- Minimum switching voltage: 17 V for signalling circuit
- Non-overlap time:
- 1.5 ms on de-energisation (between NC and NO contact)
- 1.5 ms on energisation (between NC and NO contact)
- Insulation resistance > 10 MOhm for signalling circuit
- IP degree of protection IP20 front face conforming to IEC 60529
- Protective treatment: TH conforming to IEC 60068-2-30
- Pollution degree: 3
- Height: 85 mm
- Width: 45 mm
- Depth: 92 mm
- Product weight: 0.375 kg