XALD324 Schneider Control Station
- 3 button model
- Button colours: white, red & black
- Markings: "Up arrow", "O" & "Down arrow"
- Cover colour: dark grey RAL 7016
- Base colour: light grey RAL 7035
- Warranty period: 18 months
Product Description
A dark grey control station from Schneider Electric's XALD series.
Technical Specification
- Range of product: Harmony XALD
- Product or component type: Complete control station
- Device short name: XALD
- Product destination: For XB5 22 mm control and signalling units
- Control station application: Three functions
- Colour of base of enclosure: Light grey (RAL 7035)
- Colour of cover Dark grey: RAL 7016)
- Material: Polycarbonate
- Operator profile: 3 flush push-buttons
- Operators description: White ''up arrow'' 1 NO - red ''O'' 1 NC - black ''down arrow'' 1 NO
- Control station composition:
- 1 flush push-button red 1 NC O marking
- 1 flush push-button white 1 NO black up arrow marking
- 1 flush push-button black 1 NO white down arrow marking
- Marking location: Marking on push-button
- Contact operation: Slow-break
Complementary
- Cable entry:
- 2 knock-outs for cable entry, clamping capacity: 14 mm
- 2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12 mm
- Product weight: 0.298 kg
- Resistance to high-pressure washer: 7000000 Pa at 55 °C, distance: 0.1 m
- Colour of marking:
- White marking when green, red or black caps
- Black marking when white caps
- Positive opening: With conforming to EN/IEC 60947-5-1 appendix K
- Operating Travel:
- 1.5 mm (NC changing electrical state)
- 2.6 mm (NO changing electrical state)
- 4.3 mm (total travel)
- Connections - terminals
- Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
- Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN/IEC 60947-1
- Contacts material: Silver alloy (Ag/Ni)
- Short-circuit protection: 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
- [Ith] conventional free air thermal current: 10 A conforming to EN/IEC 60947-5-1
- [Ui] rated insulation voltage: 600 V (pollution degree 3) conforming to EN/IEC 60947-1
- [Uimp] rated impulse withstand voltage: 6 kV conforming to EN/IEC 60947-1
- [Ie] rated operational current:
- 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
- 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
- 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
- 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
- 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
- 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
- Electrical reliability:
- Λ < 10exp(-6) at 5 V and 1 mA conforming to EN/IEC 60947-5-4
- Λ < 10exp(-8) at 17 V and 5 mA conforming to EN/IEC 60947-5-4
- IP degree of protection:
- IP66 conforming to IEC 60529
- IP69
- IP69K
- IP67
- standards
- CSA C22.2 No 14
- EN/IEC 60947-1
- EN/IEC 60947-5-4
- JIS C 4520
- EN/IEC 60947-5-5
- UL 508
- EN/IEC 60947-5-1
- vibration resistance 5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6
- shock resistance
- 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
- 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27